PRODUCTS

We have a wide range of products with the highest performance

Intelligent Lightning Protective Management System
(ILPMS)

Ordinary Lightning Protection System

  • - Lightning Rod, Lightning Conductor
  • - Bonding (Conduct Wire, Ground wire)
  • - SPD (Surge Protective Device)
  • - Ground Terminal - Ground Conductor
from IEC to ILMS

Necessity of ILPMS

  • - Ordinary Lightning Protection System is needed at least two semi-annual checkings. Especially in summer and rainy season that surge invasion from lightning is frequently occured, we need bonding connection and operation status checking for normal working of protected device.
  • - However, lightning arrest facilities are scattered in buildings or in various outdoor sites, such as computer centers with dense telecommunications facilities, electronics, and control devices, residential complexes, automation factories, and outdoor operation faicilites. Due to the limitations of personnel and time, it is impossible to conduct an inspection at an appropriate time.
  • - Since for the larger facilities, those consist of more complex power, communication, and signal networks, it is impossible to identity or analyze the inflow path of the brain surge; and also, it is common that we repeat the same damage situation because the follow-up is not properly within the formal range when the surge damage occured. ILPMS is an intelligent and advanced technology that has been introduced with advanced IT technologies, as a system for operating reliable lightning arrest facilities to protect power and telecommunication network facilities.

Distinction

Lightning Protection System Previous System ILPMS  
Lightning Rod
Conducting Wire
Periodical Inspection
Impossible Checking Bonding Systems
Real-Time Checking Bonding System
Check Operation Condition when Lightning &
Collecting Lightning Date
Multi-Step Digital Lightning Counter
Ground System Manual Check of Ground Impedance
Impossible to forecast Ground Performance
Real-Time Monitoring Ground Impedance
Possible to Forecast Ground Performance
Active Grounding Terminal
SPD Difficult Manage Operation Status
Cause an Accident when Lifetime is over
Real-Time Checking Operation SPD
Counting & Transferring Surge data
Self-Diagnostic Life-time & Remote Alarm
Self-Diagnostic Counter-Type SPD
Maintenance Formal Reinforce Ground or Changing
Lightning Rod Repeat Similar Damage
Forecast Accident from Lightning and
Ground Checking Weak Point and Prevent
Damage by Studying Data
Power monitoring / IBS / BAS
Interworking Software

Schematic Diagram of ILMPS

Smart Lightning Protective Management System image

Efficiency of ILMPS

Smart Lightning Protective Management System